View Single Post
  #4  
Old 02-11-2020, 02:43 AM
ppppenguin's Avatar
ppppenguin ppppenguin is offline
VideoKarma Member
 
Join Date: Oct 2009
Location: London, UK
Posts: 466
Mean level AGC, especially with AC coupling, was often known as Always Grey Control.

At the studio end, it was the job of the racks engineers to keep black level where it should be. Working an Emitron/Iconoscope camera was a difficult job. Not only black level but also tilt and bend to correct for brightness distortions within the picture.
__________________
www.borinsky.co.uk Jeffrey Borinsky www.becg.tv