Now that I've had two units for some time I've been noticing some common trends between the two.
Firstly, The second unit I bought seems to be slightly newer than my first one. Some capacitors at the same ratings are now smaller physically. But it seems any "47uf 16v" cap is suspect for leakage on both units and 99% of the time its just that one type, I don't know why.
Secondly the bottom of the unit is horrible unprotected from damage. Only a thin metal plate separates the bottom three circuit boards from being exposed. Any inpact, or drop (or placing the unit on an uneven surface) will case the frame to push upward and crack the PCBs. This was the case on Unit 2, two PCBs had some major cracks that fortunately were easily repaired.
Thirdly, I'm a little perplexed at the RWD/FF engineering design, perhaps someone here can enlighten me. If you look in the image there are three major parts to RR/FF: The idler wheel, the takeup/supply hub, and a thin plastic column powered by the drive motor. Obviously the idler wheel is rubber but the plastic on the drive column and the supply hubs are SMOOTH PLASTIC. There is VERY LITTLE RESISTANCE needed to make the hubs stop moving, hence the tape not rr or ffd. I dont know if this was done as a safety so the tape doesnt break by having the rrw/ff force the hubs to move at high speed or what, but I feel like there isn't enough grip on the idler wheel to the supply and takeup hubs to allow tapes to move at their proper speed. Last month I cheated by oiling the reels INSIDE each tape so they can roll against each other without friction but that is not a good solution.