Continued:
I slowly took the coil apart to avoid breaking any coil wires. The original internal tie points were riveted to a paper band. The paper was so dry,it just crumbled to pieces when touched. After taping off the wires and removing some layers of tape I got to the iron core which surrounds the windings. The iron core is nothing but annealed black steel wire. The old core was very rusty and weighed about 6 ounces.
With the iron core removed along with some more tape layers, I reached the now exposed vertical deflection windings. Fortunately the vertical windings are covering the horizontal coils, which I didn't want to remove.I used plastic tools to pry loose the old vertical coil. I didn't want to damage the horizontal coils underneath.
With the vertical coil and iron core removed I re-measured the inductance of the still intact vertical and horizontal coils. The vertical coil has an inductance of about 266 mh. The horizontal coil is 5.5 mh per section. I now had a starting point from which to wind the new vertical coils. I decided to do both vertical coils, since I didn't know what caused the original coil break, stress or corrosion.
|