Tube capacitance problems were addressed by neutralization (negative feedback), as in the Neutrodyne scheme. A bit later, an xtra grid was added between the G1 and plate (screen grid) to minimize G1-plate capacitance, as in the famous 24A tetrode.

Grid leak resistor is used to bleed off ('leak') excess space charge (the cloud of electrons boiled offa the filament), otherwise the tube would self-bias to cutoff. It also provides detection (demodulation) of the RF signal via the nonlinear characteristic of the response curve.