Well, as my Pappy always said, if brains were lard I couldn't grease too big a pan. I do actually have a little dyslexia/disgraphia so I'm not too surprised. And while it must be tough answering stupid questions like that imagine what it's like to be me.
So, pulled apart both of the yolks I have handy. Both measured about the same resistance on all the coils. Quite a bit of corrosion in both of them, it looks like the plastic disc that seperates the magnets from the housing is off gassing or something, both have yellow/white substance all over the place and a lot of corrosion on the metal disc. I noticed that the two yokes have different windings, one is larger than the other and may be a different guage. Just in case I replaced the resistors on the one I am using. There was a springy wire on the yoke that was on the CRT that I am using, the other had a wire to a paper that was under the CRT holder. So I made a reasonable facsimile and put that on. I also noticed that the horizontal linearity magnet was a little cocked and straightened that.
It's locking OK and is less egg shaped. What is the proper way to adjust the horiz. lin. magnet? In and out from the CRT but keep it even I assume?