View Single Post
  #11  
Old 07-26-2016, 01:31 AM
ppppenguin's Avatar
ppppenguin ppppenguin is offline
VideoKarma Member
 
Join Date: Oct 2009
Location: London, UK
Posts: 466
Live chassis sets (hot chassis in US English) were commonplace, both for radios and TVs. Saved the cost and weight of a double wound transformer. Because you guys across The Pond only use a puny 120V there was never quite the same need to keep humans away from the metalwork in the set. Here in the UK with 240V power it was a lot more important.

While it's best to connect the chassis of the set to mains neutral (cold) it's meant to be safe either way round. The antenna input is meant to be isolated with good quality capacitors in case the chassis is live (hot). Don't trust that these capacitors are still good.

Always use an RCD (GFI) in the power to sets like this. Then if the worst happens nobody gets hurt.

There are some sets where the incoming power is bridge rectified. In such sets the chassis is always at half mains (line) potential. A good trap for the unwary.

Don't assume the power switch in the set is OK. It's meant to be double pole but don't rely on either pole working. I learned this lesson at a very early age. I'd checked the chassis of a TV was safe. Turned off the switch and got a nasty belt from the chassis. The neutral (cold) side of the switch had failed int he closed position.

If you're using testgear such as a 'scope with a live chassis set then the correct way to do it is to power the set via a double wound isolating transformer.
__________________
www.borinsky.co.uk Jeffrey Borinsky www.becg.tv
Reply With Quote