I recently spent some more time with the 2073:

The 10" & 12" sensors do work when they're held down by hand, but not during normal operation. The 10" sensor doesn't even touch the record because it's sunken too far from the top of the platter.

Tracking pressure is adjusted by a spring loaded clip that can be pressed into one of a series of slots on the underside of the tonearm. A pair of pliers are useful for repositioning it. The factory default pressure was 3.3 grams. I moved it to 4.3 grams for better results. Perhaps 5 or 6 grams would be best.
__________________