Quote:
Originally Posted by Electronic M
I prefer an analog meter (I just use a Radio Snack cheapie) for this as it allows a more precise dip to be achieved. If it don't want to dip below 220mA something is probably wrong. 185-215mA is where you want to be to baby that hard to get fly.
|
Yes, an analog meter is imperative since digital meters are prone to going nuts on complex waveforms. We just used a Simpson 260 and a Pomona adapter for the cathode current.
Since we were an RCA dealer and the first imperative was keeping the damn sets working thru their warranty period, we put the power xfmr. primary tap for 'high' line voltage, and the H.out cathode current as low as possible, 200-205 ma. max.
210 ma. would have been the absolute upper limit for any degree of longevity.