First the 12HL7 shows it is cut off IMHO which gives a
high plate V so high CRT cathode so dark pix.
The 12HL7 is a 12 V tube BUT the filament is tapped so you can
run it at 6VAC in a series set.
You should get apx 6 VAC at pins 4 & 5 to ground.
Pin 6 must go to GND. Its the tap.
Next change the 12HL7 its fast & easy & eliminates it.

BTW looking at my Sams under better light I see tiny
check marks around the drives & other plate components.
Someone may have been chasing the same problem. They
DID NOT do what they should have, write down the sympton
& cure, ass hole............