Originally Posted by MRX37 View Post
I clipped a lead and tested it. If it's the boost diode, it tests open both ways.
As it will - it's a high voltage selenium rectifier, and the forward voltage drop is beyond what a DMM/Ohmmeter/Diode check function can provide.

Only two ways to check - with the set on, measure the Boost (~900-1100V - more than a DMM can handle) with a VTVM =OR= replace the rectifier and run the set.
__________________
Brian
USN RET 22YRS (Avionics/Cal)
CET-Consumer Repair and Avionics ('88)
"Capacitor Cosmetologist since '79"

When fuses go to work, they quit!