141494 are your slide knobs - sold them 4 to a pack. Moyers and Talon are out. I have a cousin's set with one broke knob, so we are in the same boat.
C104, a 3 or 4-section can goes with all sorts of problems on those XL's. The 30-volt supply feeds the MAK module (IF module) and it has to be clean. The 1500uF section in the 3-section usually goes - it's rated at 40V, we always swapped in a 2200@50V, hanging under the chassis. You'll need to isolate the 1500uf section, or swap out/stuff the whole can.
The XL - series had three different caps over the run of those chassis, all different in values. Send me the drawing number (9XXXXX-X) off the cap and I can cross it so you can check moyers for one.
I too have plenty of MA-series modules, lemme know if you need any to troubleshoot with. There is a substitution matrix, but you have mostly 001-suffixed modules, so I have the direct replacements.
The MAK was relatively reliable as a module - most got swapped because of a bad 30V supply, then the shops would swap the cap, fixing the set. Modules were non-returnable, so the customer ate a module. We had plenty of junkers, and never had to use a rebuilt module.
Be careful swapping modules - the blue/gray plastic socket housings are FRAGILE - and getting hard to find, like the slide knobs.
Cheers,
Still my favorite RCA....
__________________
Brian
USN RET 22YRS (Avionics/Cal)
CET-Consumer Repair and Avionics ('88)
"Capacitor Cosmetologist since '79"
When fuses go to work, they quit!
|