Check the power supply voltages, any of the circuit protectors "CP"s on the boards and that the microprocessor reset is working when first plugged in. Since it spins the drum, may not be doing a full initial reset, where it will spin the drum briefly and check mechanism state when plugged in, before it goes to standby ready to go.
|