ok well that does not mean anything other than caps discharging. You always measure resistance on a chassis after B+ has been off long enough to discharge, same as you always read resistance after having hooked up to let is stablize just in case there is a cap in there. you should also reverse polarity when reading resistance if it reads an odd amount when comparing to the resistance chart.
what was the pin 6 to B+ double reading?
|