There seems to be something seriously wrong with the line oscillation on this thing
Okay so now the PL504 sweep tube gently and slowly starts to red-plate (also it sounds like it clicks inside the tube)after 30 seconds of set turning on,which means the cathode current start to go a bit high,which could be caused by the oscillator running at a too high frequency ...(on pin 6 there is 160V and it should be 215V but I checked all resistor and they all fine)....
Now I suspect the two yellow diodes in the pic cause they are connected to the grid of the PCF801 and when I try-ed testing them,I got nothing on the meter,like they would be open,or was I doing something wrong ...
Also does the tube in pic look shot,its a mini-watt PCH200 AND IS CONNECTED DIRECTLY on the two yellow diodes ...IF you look the getter it has some sort of white stuff there,can that be a indication of a gassy/bad tube ??
PROBLEMS:
-cant get a clean picture,its cut and the two parts are switched around ,which could mean the oscillator is running too fast and if I try adjusting it there appear multiple pictures and the bleed into each other ...
-PL504 gently start redplate everything else from the EHT prospective seems to run fine,except for the blooming problem(could be the DY87,BUT THAT CANT AFFECT THE PICTURE PROBLEM)
-OSCILLATOR isn't running correctly and the high pitch is so loud that my ears hurt,which is another indication that it seems to run too high ...
I USED THICKER WIRE WHEN I WAS REWOUNDING THE FLYBACK SECONDARY WINDING,WHICH THE OSCILLATION FROM THE TUBES GOES THRU THESE WINDINGS ,CAN
THAT BE THE PROBLEM OF THE?,CAUSE OF THE CHANGE IN RESISTANCE AND STUFF ?? (0.30MM INSTEAD OF 0.22MM)
Quote:
Originally Posted by stusnyder
I had a similar problem with a zenith. Try different IF tubes.
|
it has a solid state IF