Oh waao. That is amazing. A virtually 'working as found' time-capsuled set.
There's a quick-and-dirty check that can assess the overall condition of critical tubes, the "7 seconds off" test.
With the set running and warmed up, turn it off for about 7 seconds, and then back on. Watch for slow width fill-out, slow H sync lock, slow vert fill, slow color lock-in, slow clearing snow etc. Borderline weak tubes will show up.

One question. Is the 6KD6 is holding steady at 200 ma., and not rising with brightness increase?

The reason for asking is - if the current does go up with brightness, it means the set uses Admiral's pulse-feedback HV regulation which historically was very trouble-prone.
But if it uses the traditional 6BK4 shunt regulator, no problemo.

Last edited by old_coot88; 01-29-2015 at 02:05 AM.