Before you remove the part;
Does the part look age appropriate with the other parts already in the set....?
Do the solder joints look undisturbed...? Was it original looking in its installation...?
If it perhaps looks newer, or if the solder joints look recently disturbed.... Then is there
a possible nearby location where this part may go....? As in, did someone accidentally
put this part back in the wrong spot making a previous repair....?
If it's connected off the cathode of the vert output, 100uf cap, (it's the only 100uf
cap I see in the schematic clip posted above) Then, the set had a minor
linearity issue, or a sync issue and someone fudged the circuit.... I can't
see it making a really big difference given the values of the other resistors
to ground in that area...
Remember ground and voltage sources are both looked at as a sink as far as
signal goes..... If it's a voltage source than what, the screen on the sync tube
must have been floating too low.....
Fix the set, then run it without it, and then put it back and see what it does....
At that value it ain't gunna make that big a difference...
See what happens.... The guy that put it in was either a schmuck, or a genius!
.
__________________
Yes you can call me "Squirrel boy"
Last edited by Username1; 12-22-2014 at 03:30 PM.
|