Quote:
Originally Posted by Electronic M View Post
There are different kinds of 'instant on' wiring depending on the year and maker. Most tube/hybrid instant on sets ran the heaters at ~half voltage when the set was turned off....There would still be warm up time, but it would be much shorter and would be called "instant on". I've never seen a set that had instant on where that term was literal, though it would not surprise me if some of the solid-state era sets with that feature left the CRT heater on full blast all the time.

I have some 'instant on' sets (proclaimed to be so in the manual) both tube and hybrid, they keep the tubes lit at half voltage when the set is off, and they have a warm up time (a short one).

It is common practice on this forum to refer to any set that, by design, keeps tube heaters lit to some degree while the set is turned off, as an 'instant on' TV set regardless of actual warm up time.
I HAVE seen a pretty much "instant" instant on set. The RCA vertical SS chassis of the early 1970's, such as CTC 48,58,68 and such. As SOON as you turned the set on, in maybe ONE second--the raster appears. NO warming for HV--since they use a tripler. In fact--you could usually see the end of the degauss action--they were so quick. (this of course is assuming the set had been plugged in for several minutes at least, before being turend on, to give time for the tube to warm up).