This cord failure may have been caused by the reduction in conductor strands due to most being broken. The remaining few strands have to carry 2 amps (18 gauge cords are usually rated for 7 amps) and likely acted like a fuse, heating up, opening and then arcing to cause that much damage.
The stress at the interlock cap is very high. The cords are pulled enough in its 53-year life to have been severly compromised. I have many sets with cords that look OK but some do have the green slime (copper oxide?) but I hate to remove an OEM part unless I notice obvious tension damage or exposed conductors.
With old radios, and I sell quite a few, its easy to replace the pigtail (non-interlock) and put on some appropriately colored 18/2 SPT cord with a vintage-looking plug, be it polarized or not. Otherwise, if Im feeling cheap, I liberate a polarized one from a derelict chinese appliance, which are never in short supply.
This "event" with the 1961 Zenith gives pause because it probably looked OK. Collectively, we would do good to find some NOS replacement interlock cords and replace them as a matter of course when selling a set. I would never wire one direct, bypassing the interlock device.
__________________
"When resistors increase in value, they're worthless"
-Dave G
|