Quote:
Originally Posted by Geist
Hi All;
I have a 8T244, which is like yours.. On the other site, I have been told not to plug mine in any more until I Re-cap it.. I had run it for hours at a time about 3 to 5 years ago when I last had it on the table to work on.. I would be interested in what you did to Re-forn your caps.. I can't say it will help my set, but I can look at what you say and then decide.. I also had problems with it arching around my Flyback, and even after doping and such it sttill would arc a little.. So, I finially just put an old Bicycle inner tube along the top around to the bottom of the flyback, and no more arching.. I know that some would scoff at that, but it works.. 
THANK YOU Marty
|
I have owned and regularly used an 8T243 for forty three years. It still has its original electrolytics (all of them) and it works fine. I replaced the paper capacitors in the early '70's with (then) brand new Sprague Orange Drops.
I have cleaned out the HV cage every decade or so. Are you seeing actual arcing or is it a corona discharge (eg hissing)? Problems or corona are generally due to contamination (dirt) or sharp points. Making sure everything is clean and connections are well rounded eliminate the problem.