Heath kit. Pretty much any old school cap tester should work, just need something that has a leak test that goes up high enough (think mine is 450v tops). Some testers use an eye tube, others a meter, the meter is prob better, I ofter will put a current meter in series with the cap to see exactly how much leakage there is (even with a fully open eye they will leak some). comparing to a new cap gives you an idea of how good an old one is. I recall there is a table somewhere that shows the allowable leakage in mA by capacity.
|