Success! I replaced the cap on the horizontal board with the correct value, but the HOT was still red plating. I pulled the 6DQ5 and found that I had a dead horizontal oscillator. After futzing with it for a while, I discovered that the NOS 6CG7 that I had installed was the culprit. It still tests fine but was no longer working in the circuit. I put the old, weak tube in place and the oscillator fired right up. This time, I was able to easily adjust the sine wave coil for the proper waveform:
Now the horizontal lock is nice and stable with the control in the middle of its range. the horizontal jaggies seem to have disappeared. There are now just a few "maroon drops" remaining and things are looking pretty good:
I still need to go through the entire purity/convergence set up. I discovered that none of the hairpin purity magnets are missing after all. A couple had been moved to normally unoccupied positions. I think they need to be remagnatized, too.
Thanks again for the help!
-Clark