I agree with Compucat, the pincushion problem (and on your set too, Matt) is probably one or more bad electrolytic capacitors. The best way to test electrolytics is to use an ESR meter, but without a schematic diagram, you can try subbing spare caps across various ones on the board near the pincushion pots and look for results on the screen. (You need to use an isolation transformer when you do this, or be VERY careful to not touch anything in the set while it is plugged in!) If Sony sets from that era are consistent with newer ones, the caps you want to check will have numbers in the 500s (c505, c512, or similar). Let us know if you have any success.
__________________
Chris

Quote from another forum: "(Antique TV collecting) always seemed to me to be a fringe hobby that only weirdos did."