Quote:
Originally Posted by vts1134
...unless I am reading something wrong ALL of my heaters and the "x" lead out of T1 are shorted to ground. The "x" lead from the transformer goes to a terminal strip and is soldered to three leads that run to the heater pins. When I disconnect those leads from each other every one of them reads shorted to ground including the lead from T1.
|
OK, here's what's going on: you're reading DC resistances so low that they show 'short' on your meter. All those tube heaters in parallel will show very low DC resistance, as will the 6.3V winding. But rest assured there is no short. If there were the tube heaters would not be lighting, and the 3 amp line fuse would blow.
Now on that 12AU7 video tube (V6), both heaters are lighting, right?