The best place to check will probably be where the regulated B+ enters the flyback transformer. It will be the primary winding of the flyback with one end connected to the HOT collector and the other end will be the B+ input. There may also be a tap on the primary winding to provide the 200 volts to the video output stage. This is the way most solid state TV flyback transformers are connected.
|