View Single Post
  #24  
Old 12-25-2010, 04:01 PM
ctc17 ctc17 is offline
VideoKarma Member
 
Join Date: Jul 2009
Posts: 1,615
Looks good! Im going to attempt a chroma alignment on mine now. Align the chroma bandpass, or at least try.


Sylvania, Vertical, Caps. The orange drops go bad.
Here are my notes on my tube sylvanias take what you can from it.

Sylvania 22 inch color console CE36-K Sams 1072-2. Tin Whisker shorted AGC pot, blew open short with b+, open 1.5 meg Red screen pot replaced with fixed resistors. Verticle hold issue, changed c38 and c41 .0033uf caps in the feedback circuit. Vert hold was all the way counterclockwise and would fall out of correctability as set warmed up. Whisker shorted vert linearity pot. Still has a minor vert linearity issue at top. Horizontal output Cathode current 200ma, sams lists 280ma. Traces on boards very fragile and some came off on caps I replaced. Cabinet and CRT are in great condition. Great color picture, maybe the best I have seen on a color tube set. Problem is vert is running to slow. I have the vert hold control all they way closed (grid at -5volts not -10) the picture will lock when the set is cold. After on for 45 minutes it drifts to a point where it starts skipping. If I decrease the size it will lock and stay.
Reply With Quote