Quote:
Originally Posted by ctc17
Did you watch my video on how to check the transistors?
|
Yes, thank you for posting it. As I said, I am seeing some amount of continuity between C & E, in both directions... Even if I have mis-identified E vs. B, I should not be seeing any continuity with C in both directions, correct?
Quote:
The circuit breaker is a BAD idea. Its response time is much much to slow. Where a fuse will blow in quarter of a second the circuit breaker will hold on for several seconds and cause more and more damage,
Get that out of there and put a regular fuse holder and AGC style fuse in, and if a 3.5 amp is not available go with a 3 amp.
Ohh, dont forget the light bulb trick I told you. That will save you a major headache.
Yes on the transistor case. On diode check you should get no reading from C to E, it should be open. Emitter, Base, Collector. Non of them are grounded.
|
Noted. I'll change it out and try the light bulb.
As I mentioned, I haven't the time nor inclination to shotgun all the caps in this thing. I don't think I learn anything that way, and it's not all that "fun". If that's the best we can do for diagnosis, this console will probably just end up on a curb.