Is that one of the infamous two-stage IF sets? Sears had one model year of rectangular (25A sets) that had only two IF stages. AGC was tied to only one of them - not a problem on an antenna, but when cable TV came around, lots of AGC and IF overload issues. We used to carry around a Winegard attenuator to show the customers that it WAS cable TV that was doing the overloading - something like +21 dBm of cable signal at one customers house. They could pick up cable on a portable across the room with the cable radiating that way. We put a total of 19dB of attenuation to get the customers Sears set to like the signal.
I don't recall ever seeing a flyback go bad in one of those sets - just vertical issues, and the usual dirty tuner, bad CRT or lightning damage.
Cheers,
__________________
Brian
USN RET 22YRS (Avionics/Cal)
CET-Consumer Repair and Avionics ('88)
"Capacitor Cosmetologist since '79"
When fuses go to work, they quit!
|