An LG tech I worked with a while back called them error return modules. It makes more sense to consider then erase pulse. I dont know what would be considered error return anyway.

But on the maldischarge issue, set the tv in whitewash in the menu. Then do ground zero setup. Probe Va and Vsc off the PS going to the Y sustain. The label on the panel will tell you correct voltages. After those are set, goto the Y sus. Measure Vs and VSC off the tp. Use the above referenced website, (very helpful). Look up your model series to see where those voltages should be. After all that is done, check the modules 18v. There is a test point. If you are seeing anything under 18, like my set is at 16v where 18 should be, the modules will heat up quick. This is primarly caused by leaky lytics on the sus board. sometines the cap in question could be SMD. Got mine to 17.8v or so and called it a day. If you have access to an o scope, use it! Probe the TP for the Y waveform. You will prob notice alot of the maldischarge will dissapear. If you still have it, could be bad buffer boards or they are being overdriven.