well I went thru it all but one of the ecaps tested fine, I was sure the vert size was going to be a weak bypass cap. Oh well. I tested the .1 coupling cap from the vert osc to the vert out, tested good. I know the lineairity adj can interact with the height (at least on some sets) so I will try adj that a bit to see if I can fill it in. the only issue is the space is on the bottom of the set and IIRC lin generally streatches the top.
I did not check the voltages but will do that when I put the chassis back in the set.
The was one weak ecap section a 50uf off the AGC center lug pot. it was about 10uf (can marked 50uf) since it was not leaking I just tacked a 47uf on and will see if that effect the contrast any.
I have a CTC service manual, but if anyone has a Sams with resistance readings I would appreciate a scan of that sheet.
I did find one stake near the 6GH8 tube that was loose, perhaps will account for the intermittant color sync issues.
there was also a NP 5uf cap in the pin cushion circuit that I tested (looks like a Ecap) with a very high power factor on the eye tube cap tester. But since the pin cushion looks ok I just left it. I have a couple more 6GF7 tubes (dual triode vert osc/vert out) that I could try if the lin adj does not pan out.
I was kinda shocked to find all those tube ecaps to be in good shape, I expected them to be leaky but all test ok.
one thing that looks a little fishy is the vert out tranny, looks very toasty. It sit next to the HV regulator tube so I dont know if that tube gets hot enough to toast the tranny or if the tranny may have gotten hot enough to short a few windings (and there by cause the reduced vert height, geez I hope that is not the case).
Last edited by DaveWM; 05-16-2010 at 11:45 PM.
|