Those caps that are on the flyback were originally white tubular caps. I think there are 5 of them in parallel (3 on the flyback and 2 under the chassis). They go from the HOT collector to ground and if they open, the HV will skyrocket and you'll lose the CRT. Since there are 5 different caps, you usually get some form of warning in the way of picture width if one opens. It's recommended that these be replaced with orange drops of the same rating. The early production vertical chassis sets used one large white safety cap that would suddenly blow open, causing the HV to run very high, which took out the CRT and other parts. That cap was quickly upgraded to an orange drop.
I've also seen the HV triplers fail in these. I think tripler failure was more common down here in the South where the humidity is very high.
Except for other isolated part failures, these sets were trouble free except for what I mentioned.
|