The Magnavox has a 100 mfd 160 volt electrolytic bad near the large heat sink in the middle rear of the set. Most of the time they tend to swell and vent out of the top. Dark sccenes tend to set off the HV protect and that causes squiqly pictures
Your Admiral may use the 3 lead degauss thermistor (black square with three tabs soldered to the board. These break loose and cause intermittant trouble with purity. If not, look for bad solder around the thermistor if it is a two lead
|