Quote:
Originally Posted by ChuckA
If everything else checks OK make sure you have filament voltage to the 6AL5 (V123). This filament has a 2.2 ohm resistor in series and the first set I had sync problems with drove me nuts till I noticed the tube wasn't lit.
Chuck
|
That's a good point. The one in my Sylvania was bad too. It was one of those early wire-wound types.
I think they do this so that the 6AL5 warms up more slowly than the rest of the tubes. Otherwise, it could lock in on a harmonic of the horizontal frequency.