Quote:
Originally Posted by radiotvnut View Post
Check these items:

A. All four bridge rectifier diodes. One or more could be shorted.
B. Horizontal output transistor for a short.
C. Regulator SCR in the power supply for a short
D. Shorted degaussing coil. Rare, but, it does happen.
E. Shorted degaussing thermistor. You can eliminate D and E by taking them out of circuit and seeing if the set will power up.
F. Shorted main filter cap
G. Shorted AC line choke
H. Shorted "across the line" cap.

If the HOT is shorted, resolder the horizontal driver transformer and everything else around the HOT. Also would be a good idea to check/replace and electrolytic caps in the 130V B+ line. If you do all of this and it blows the HOT again, the flyback is likely bad.
With the coil and thermistor removed, I would just short across their leads where they were removed?