On the matter of the 6f6, here is a tube diagram of that little feller:
http://www.nostalgiaair.org/tubes/6f6.htm
pins 2 and 7 being the filament, you will pretty much have your multimeter reading as a short to ground for both of those pins while the tube is installed, as the filament is of very low resistance. If both pins 2 and 7 still read as a short to ground when the 6f6 tube is pulled, then you could have a problem.
On the issue of all of the other pins, save for 5 and 6 being grounded; pin 6 isn't used on this tube, though there may still be things soldered to it, being used as a tie point for other parts in the circuit. Pin 5 is the signal input grid, so that makes sense that it wouldn't be grounded. Looking at the schematic, it appears that pins 3,4, and 8 should not be grounded. But we'll mess around with that issue a bit more once your transformer issues are cleared up.