there is a .047 cap coming off the screeen of the HOT to ground, perhaps some kind of decoupler? I do not recall checking that one. It looks like a decoupling network as after the cap there is a 8200 5w resistor then it goes to the 245v B+, the Screen of the vert output is connected directly to the 245v source.
I am guessing the .047 cap will work as a decoupler at the freq of the HOT.
If the cap was bad it would have to be open (if it was leaky I would have a drag on the B+) I will try just jumping another cap and see if it has any effect. It's one of those brown dipped one, and I already had a couple bad one of those (leaky, .22uf 200v). The 400v ones tested ok, but I did not test that one.
all the filter can caps and doublers were replaced. as well as the electrolytic cathode bypass caps .
|