Quote:
Originally Posted by freakaftr8
... could filter caps cause the cathode current to be high?
|
Don't see how. Bad power supply filters would show up as hum bars or "bend bars" slowly creeping up through the picture.
Quote:
|
I use a DMM rated max 400ma. I get reading from 221 to 241ma.
|
I would get another meter, preferably analog, to double check that current. Digital meters can go nuts if there's any strange waveforms present in what they're trying to measure. There's a helluva lot of horizontal sawtooth and even RF in that current, and even if you have a cap across the meter, some of that stuff can still get past it.
If the current is really running that high, the tube is gonna be
sizzling hot. Old techies could tell if the tube was running too hot just by holding the back of a hand next to it.