Quote:
Originally Posted by ctc17 View Post
As the horizontal drive tube/oscillator ages the cathode current goes up as the output tube looses drive.
Not necessarily. The first sign of the H.osc tube going weak is that the osc. will be off-frequency when the set comes on from a cold start; it'll take a little time for the lines to straighten up and the pic to lock in. A quickie test of the H.osc tube is to turn the set off for several seconds, then back on. If it comes on with lines before locking in, the tube is getting a little weak. If it comes on fully locked, the tube is good. A weak osc tube will generally cause off-frequency problems before drive level to the HO tube is affected.