View Single Post
  #3  
Old 10-23-2009, 06:18 PM
Findm-Keepm's Avatar
Findm-Keepm Findm-Keepm is offline
Followin' the Rules...
 
Join Date: Jun 2007
Posts: 2,857
Quote:
Originally Posted by radiotvnut View Post
Look for an electrolytic cap on the order of 47 uf, 250 volts located somewhere around the relay. Several months ago, I rescued an '89 Sony from the salvation army that had a buzzing relay and would not turn on. One new 47 uf cap fixed the problem.

On the degaussing issue, resolder the degaussing thermistor. Very common fault on '80's and '90's era Sony's.
The ground connections to the tuner were also a problem, as were the connections to the vertical chip. We saw a lot of "post-military-move" Sony sers that only required a resoldering of the big three - degaussing thermistor, vertical chip, and the tuner. Later, JVCs were the solder scrooges.

Cheers,
__________________
Brian
USN RET 22YRS (Avionics/Cal)
CET-Consumer Repair and Avionics ('88)
"Capacitor Cosmetologist since '79"

When fuses go to work, they quit!
Reply With Quote