update on this set, I think I lost a lot of post but it is the one that was having the hula problem, or snaking or maybe even weaving.
bottom line is there was a low freq low amplitude wave that would work thru the screen. You could see it on vertical lines. the wave would repeat about every 15 seconds and would deflect the vertical lines (like a foot ball field) about 3/16 of an inch.
I was able to get rid of it if I powered the vert sync tubes heaters with DC.
no HK shorts (swapped tubes from a working set).
tried cleaning PCB traces along the filament trace, no help
had all new E caps (filter/decouple/doubler)
finally got it licked by adding a direct ground connection from the two vert tubes to the chassis ground.
Those two tubes use the PC traces for a heater ground return, and the PC trace is grounded via some solder fingers that press against the chassis.
I may have been able to just tighten up the screws, but I figured the direct wire to chassis was more of a sure thing. Seems kind of lame to rely on just a press contact point for a ground. The horz osc tube had its own factory ground wire, and did not rely on the pcb for a ground path on the heater.
any way it did tighten up all the pcb screws on all the boards jic.
anyway learned something new, small problems (the wave was very minor but there) often have small causes (I prob could have fixed it by just tighting up the screws).
Small causes can still be hard to find, maybe harder since they are not obvious. But anyway you can bet for now on all pcb screws will be checked 1st thing.
|