I can't find a horizontal position adjustment; but, there is a B+ adjustment. If this adjustment is off, it will effect the horizontal size. To adjust, connect a DC voltmeter to TP91, low side to ground. Adjust picture for minimum brightness. Adjust B+ adjust control (R808) for 130 VDC +/- 1.5 volts @ 120 volts AC applied to receiver. This control is located close to the flyback and B+ fuse.
It is important that the B+ be correct. Do not use the B+ adj. control to compensate for a horizontal width problem. Also, the condition of capacitors C511, C512, C517, and C518 will effect horizontal width.
|