Quote:
Originally Posted by Big Dave
Leave the tubes in. I start about 40 volts and raise it by 5 volts every 15 minutes. If a can starts getting warm (not heat transfer from the tubes), I abort. Now, I can reform the lytics. I do disconnect the top cap from the hor out. If the hor out doesn't have a top cap, I tie in the heaters of an equal voltage tube (series string) or remove it.
|
On the set that I'm concerned with the HOT is a 6BD5GT, so no top cap. The heaters are all parallel so I can just remove the tube.
If I remove the HOT then I want to remove the 6Y6G in the RF HV because I don't want 9.5KV on the CRT if there's no scanning. The rest I would leave in. Well, maybe I'd take out the vertical output, but I think the HOT is the most important one.
Thanks for the info,
John