Steve,
Finished up the TRK tonight, 53 caps changed and 1 electrolytic can. Picture is pretty good, if you watch it in a dark room.
My problem with poor horizontal and vertical sync ended up with a 6N7 that developed a plate to cathode short after running in the set for an hour, pulled the plate voltage down to 16v on the sync amp. Changed the tube and locked right in.
One think I noticed, maybe you can tell me if it is common with this set, watching the video output signal from the 6V6 the video signal clips as the brightness control is turned up. This only happens on the output (plate) of the 6V6, signal on the grid is constant.
Chuck
|