Posts: 2,094
Ive seen this before. If you adjust the horizontal hold control, you can move that bar off the screen, and it might shadow over to the otherside. Its horizontal blanking problem. I had this same problem on a 20Y1C48 and was caused by a leaky horizontal phase detector diode. In these sets, the phase detector diode is two individual glass germaniums. Try subbing the 6U10 first. There are probably only 3 black BB caps in that chassis. I restored a 25LC20Q a few months back and only had 3 under there. I suggest not recapping the entire set. The only time I recap a set is if it has BB's or paper/wax caps. That chassis has many mylar caps, and those are very quality good caps. Same with the electrolytics. I check ESR on the originals and if its good, the cap stays. 95% of the time, they check good on the 60's TV sets. Ive been using alot of my old sets for YEARS on the original lytics with no problems. There was a considerable quality/reliability improvement in components by the early to mid 60's compared to the 50's. TV's.
Im big on keeping a TV all original if at all possible.
__________________
I tolerate the present by living in the past...