View Single Post
  #13  
Old 08-23-2004, 12:14 PM
Kevin
Guest
 
Posts: n/a
I believe that you need to gradually remove the current from the degaussing coil so that the tube doesn't become magnetized.

When I prototyped the circuit with a PTC thermistor, I monitored the voltage across the degaussing coil and it did not drop. I then disconnected the power cord which abruptly removed the magnetic field and the next time I turned on the set, the colors were impure - aka the face of the tube was magnetized.