It seems like the flybacks may be susceptible to trouble but I wonder what the most likely cause of the flyback stress is? Excess horizontal output tube current draw or HV regulator problems? I've got one Magnavox table model with a similar chassis and there were problems in the 6BK4 grid/cathode circuit which were causing the flyback to overheat (burning smell)
I was able to fix it and reduce the current draw in the 6BK4 circuit to the normal 800-1000 microamps and it seems to be operating OK now.
On another Mag. console with a similar chassis the 6BK4 was drawing so much current there was no picture. It was just loading down the HV too much. It seems like it needed a new 6BK4 plus repairs to the grid/cathode circuit
Last edited by Chad Hauris; 01-13-2008 at 02:05 PM.
|