Yes, and that winding is not grounded. It is insulated at 2500 volts because RCA put the cathode on the filament to prevent arcing.Arcing was a big problem with those tubes. If the winding is leaking to the chassis it would cause a short in B+, which would blow that fuse, and make alot of other stuff un happy until it does. Bypassing fuse is very bad on the flyback. Not a good thing. You MUST stay with the original value .25A,250 slo blo fuse. Clips can be had to adapt the new fuse to the old pig tail fuse.
Looks like you are past the guess it could be this part point. Start tracing, do resistance measurements in circuits, etc.. You obviously have a short.
Bill Cahill Get a capacitor tester for those new caps you installed. My guess still would be that one, or, more of them has failed. It only takes one to cause a short.
Try unplugging the yoke, and, put a jumper wire over the two pins that connect the 5U4 the the rest of the set.. Power it up, with a proper fuse, and, see if it still blows. If so, the short is somewhere else.. Is it your vertical, or your horiz. that failed? If it was truly the entire horiz.then, you shouldn't get a vertical line..It has to work at least a small amount for the flyback to work.. Is flyback wired properly? Did you make any mistakes in your wiring? The cloth covered wires, and, I warn you, they have damper pulse on them, that go from the damper filament to the terminal strip below that has thw cloth wires from power transformer, and, those wires, tend to fail, and, rot.
Also, I doubt your problem is that coupling capacitor. That's a special capacitor rated at a very high voltage, by the way. I believe it's rated at something like 2500 volts.
There is an extremely high pulse on the plate of the horizontal output tube.
Bill Cahill
__________________
"Tubes are those little glass things that light up orange unless there is a short.. Then they light up all pretty colors..."
Please join my forum.
http://www.tuberadioforum.com/
|