Hey Guys, just wanted to update.. I had my suspiciouns about the HO tube, on the meter, it would read great (115%), after a minute of being on the meter it kept dropping, so I replaced it with NOS. The srunken rater thing went away upon startup, horiz is correct now. The only deal is that after 10 minutes of being on the horiz wants to flutter and come in and out of phase a little. After 30 minutes, it's hard to lock, and gets really touchy. Cathode current is staying at an even 214ma to 210ma. The grid voltage stays at -54 vdc. At the transformer tap on the pc board is labeled 120v, i read 88vdc from the trans. Now this reading is taken before I power up the set, powering it up oes not change that voltage reading. Another tap going to the board is labeled 128v, I get nothing, ever... (and the set runs).. Any ideas? Also vertical hold flips like crazy upon startup and stabizizes after a couple minutes, if I stabilize it upon startup, it will start rolling when the set warms up..
Thanks
__________________
Honey, turn on the tv.. I'm cold!
|