Yes, you need to test capacitors out of the circuit for anything other than a short, in most cases. The only test that is usually reliable in-circuit is for ESR in electrolytics. Resistors can be measured in-circuit to some extent, to test for increased resistance (or open of course).

The disc capacitor you mentioned is .01 microfarad. Values with a decimal number are always in uF, whole numbers are in picofarads (once called uuF) More recent caps have been marked with a 3-digit number representing the value in pF. The first two digits are the value and the third digit is the number of zeroes after the first two. (473=47000 pF=.047 uF.)

I have found bad disc caps a number of times in my work (and Mylar/film types too), but not nearly as often as electrolytics.