Quote:
Originally Posted by andy
I assume you meant to say to adjust the vertical size control, not vertical lin? Do those sets even have a vertical ine control? Assuming is vertical overscan and the linearity is good, that may be all that is needed. There should also be a width coil near the flyback that will take care of any horizontal overscanning. It will be the only large adjustable coil in the set.
I have seen some other bad caps in those sets that caused excessive overscanning with poor vertical linearity. It's been a long time, but I think they were at the edge of the board near the vertical IC.
|
My schematic indicates R2112 as a vertical linearity control. I can't find a vertical size or vertical height control anywhere. Here are some cap suspects if adjusting this control does not solve the problem:
C2108 - 4.7 uf
CX2109 - 1000 uf
CX2110 - 100 uf
C3248 - 3.3 uf
CX3208 - 4.7 uf (bi-polar cap)
The "X" in the location number indicates these caps to be critical values and should be replaced with a cap of the same capacitance value and at least the same working voltage. Those caps in the 2100 series stand out in my mind as being possible suspects. CX3208 is a big cap located at the front of the power supply board. All the rest are located around the vertical linearity control and the vertical output IC. This IC is a 13 pin device mounted on a heatsink.
R3249 is the Horizontal width adjustment in this set. Look towards the left hand side of the power supply board. You'll see a larger size electrolytic cap. Behind the cap is a small transformer. Behind that is a small electrolytic cap. Behind that cap is the horizontal width control. Behind the control is the vertical IC heatsink.