Quote:
Originally Posted by 3Guncolor
I have found that instant on never seemed to kill Zenith tubes. Don't zap the tube unless you can't get the gray scale to track. If I remember correctly the transformer for the instant on is part of the filament supply when the set is running so it is not removable.
I’m sure it can be setup to turn on and off with the main transformer. Don’t forget to check the white high voltage hold down caps on that chassis I bet at least one is bad and your high voltage will be too high.
|
Those caps are certainly on the "hit list" before I'm done with the set. I've only seen one Zenith CCII with a dead tube. It was an early upright chassis with instant on and I think that tube was a non-Zenith. Probably installed when the 4 lead white cap failed and caused the HV to wipe out the original CRT. Still, that dead tube rejuved good and I was able to find a home for the set. I don't plan to rejuv the tube in this set unless I have no other option. There used to be a idiot tech in this town that would rejuv the crap out of later model tubes when the CRT was not causing the problem. I'll bet he caused the early death to a lot of CRT's!